Feasibility of Distorted Born Iterative Method for Detecting Early Stage of Heart Failure

dc.authorid Egemen Bilgin / 0000-0003-3517-6164
dc.contributor.author Akıncı, Mehmet Nuri
dc.contributor.author Bilgin, Egemen
dc.contributor.author Joof, Sulayman
dc.contributor.author Doğu, Semih
dc.date.accessioned 2021-08-24T07:44:32Z
dc.date.available 2021-08-24T07:44:32Z
dc.date.issued 2020
dc.department Mühendislik Fakültesi, Elektrik Elektronik Mühendisliği Bölümü en_US
dc.description IEEE MTT-S International Microwave Biomedical Conference (IMBioC) en_US
dc.description.WoSDocumentType Proceedings Paper
dc.description.WoSIndexDate 2021 en_US
dc.description.WoSInternationalCollaboration Uluslararası işbirliği ile yapılmayan - HAYIR en_US
dc.description.WoSPublishedMonth August en_US
dc.description.WoSYOKperiod YÖK - 2020-21 en_US
dc.description.abstract In this paper, we analyze the feasibility of using microwaves to detect early stage of congestive heart failure, which causes water accumulation in the lungs. To this aim, a slice from realistic human torso phantom, which consists of all human tissues and organs, is considered. Constitutive parameters of the phantom are calculated by multiple order Cole-Cole model at operating frequency. Then, the scattered field is calculated via method of moment and a 30 dB additive white Gaussian noise is added to create a more realistic scenario. In the solution of inverse scattering phase, distorted Born iterative method is utilized. The presented results show the feasibility of the proposed method. en_US
dc.description.woscitationindex Conference Proceedings Citation Index - Science en_US
dc.identifier.citation Dogu, S., Bilgin, E., Joof, S., Akinci, M. N., (14-17 Dec. 2020). Feasibility of Distorted Born Iterative Method for Detecting Early Stage of Heart Failure. 2020 IEEE MTT-S International Microwave Biomedical Conference (IMBioC). p. 1-3. en_US
dc.identifier.doi 10.1109/IMBIOC47321.2020.9385045
dc.identifier.issn 9781728158662
dc.identifier.scopus 2-s2.0-85099884880
dc.identifier.scopusquality N/A
dc.identifier.startpage 1-3 en_US
dc.identifier.uri https://hdl.handle.net/20.500.11779/1538
dc.identifier.uri https://doi.org/10.1109/IMBIOC47321.2020.9385045
dc.identifier.wos WOS:000675835900046
dc.identifier.wosquality N/A
dc.institutionauthor Bilgin, Egemen
dc.language.iso en en_US
dc.publisher IEEE en_US
dc.relation.journal 2020 IEEE MTT-S International Microwave Biomedical Conference, IMBioC 2020 en_US
dc.relation.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Pulmonary edema detection en_US
dc.subject Distorted born iterative method en_US
dc.subject Microwave imaging en_US
dc.subject Congestive heart failure en_US
dc.title Feasibility of Distorted Born Iterative Method for Detecting Early Stage of Heart Failure en_US
dc.type Conference Object en_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Feasibility_of_Distorted_Born_Iterative_Method_for_Detecting_Early_Stage_of_Heart_Failure.pdf
Size:
2.11 MB
Format:
Adobe Portable Document Format
Description:
Proceeding papers

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: