Out-Of Seismic Performance of Bed-Joint Reinforced Autoclaved Aerated Concrete (aac) Infill Walls Damaged Under Cyclic In-Plane Displacement Reversals

dc.contributor.author İlki, Alper
dc.contributor.author Demir, Uğur
dc.contributor.author Halıcı, Ömer Faruk
dc.contributor.author Zabbar, Yassin
dc.date.accessioned 2023-10-18T12:06:14Z
dc.date.available 2023-10-18T12:06:14Z
dc.date.issued 2023
dc.department Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü en_US
dc.description Scientific and Technological Research Council of Turkey (TUBITAK); [1649B031700370] en_US
dc.description All of the sources of funding for the work described in this publication are acknowledged below: 2211-a, scholarship reference number 1649B031700370. PhD scholarship granted to Omer Faruk Halici en_US
dc.description.PublishedMonth Nisan en_US
dc.description.WoSDocumentType article
dc.description.WoSIndexDate 2023 en_US
dc.description.WoSInternationalCollaboration Uluslararası işbirliği ile yapılan - EVET en_US
dc.description.WoSPublishedMonth Nisan en_US
dc.description.WoSYOKperiod YÖK - 2022-23 en_US
dc.description.abstract The infill walls made of Autoclaved Aerated Concrete (AAC), which is a lightweight, fire resistant and energy efficient material, provide effective insulation solutions for building types of structures and becoming more and more popular in earthquake prone regions. Although the number of experimental tests examining the seismic response of clay brick infills is extensive, the amount of prior research on infill walls built of AAC blocks is rather limited. Past research revealed that the use of bed-joint reinforcement is one of the promising solutions to improve the global seismic response of masonry walls by enhancing strength and displacement capacity. In this study, the out-of-plane (OOP) seismic performance of AAC infill walls with flat-truss and innovative cord-type bed-joint reinforcement is experimentally evaluated. Also, consideration is given to the prior in-plane (IP) damage, which was found to degrade the seismic performance of infills in OOP direction. For this purpose, three IP and four OOP, in total, seven experimental tests were performed on four full-scale AAC infill wall specimens. The test parameters were selected in such a way as to make it possible to parametrically compare the OOP performance of AAC infills with flat-truss and cord-type bed-joint reinforcements with unreinforced AAC infill walls, together with the effect of prior IP damage on the OOP response of unreinforced AAC infill walls. It was found that the use of innovative cord-type bed-joint reinforcement improved the OOP strength to a similar extent to what was obtained from the truss-type reinforced specimen. In terms of ultimate displacement and energy dissipation capacity enhancement, the specimen with cord-type reinforcement performed better. In addition, the damages formed due to IP cyclic displacement reversals up to 0.005 drift ratio, which is defined as the drift limit for buildings with brittle infill walls in certain design codes, resulted in a significant reduction in the OOP strength and stiffness properties of AAC infills. The theoretical OOP strength calculations were found to provide unconservative strength values for the IP-damaged specimens. en_US
dc.description.woscitationindex Science Citation Index Expanded en_US
dc.identifier.citation Halici, O. F., Demir, U., Zabbar, Y., & Ilki, A. (2023). Out-of-plane seismic performance of bed-joint reinforced Autoclaved Aerated Concrete (AAC) infill walls damaged under cyclic in-plane displacement reversals. Engineering Structures, 286, 116077. en_US
dc.identifier.doi 10.1016/j.engstruct.2023.116077
dc.identifier.issn 0141-0296
dc.identifier.issn 1873-7323
dc.identifier.scopus 2-s2.0-85162234295
dc.identifier.scopusquality Q1
dc.identifier.uri https://doi.org/10.1016/j.engstruct.2023.116077
dc.identifier.uri https://hdl.handle.net/20.500.11779/1990
dc.identifier.volume 286 en_US
dc.identifier.wos WOS:000992523800001
dc.identifier.wosquality Q1
dc.institutionauthor Halıcı, Ömer Faruk
dc.language.iso en en_US
dc.publisher Elsevier Sci Ltd en_US
dc.relation.journal Engineering Structures en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Behavior en_US
dc.subject Bed-joint reinforcement en_US
dc.subject Experimental seismic performance evaluation en_US
dc.subject Frames en_US
dc.subject Autoclaved aerated concrete (aac) en_US
dc.subject Infill walls en_US
dc.subject Sliding joints en_US
dc.subject Capacity en_US
dc.subject In-plane and out-of-plane behavior en_US
dc.subject Masonry en_US
dc.title Out-Of Seismic Performance of Bed-Joint Reinforced Autoclaved Aerated Concrete (aac) Infill Walls Damaged Under Cyclic In-Plane Displacement Reversals en_US
dc.type Article en_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
1-s2.0-S0141029623004911-main.pdf
Size:
17.08 MB
Format:
Adobe Portable Document Format
Description:
Full Text- Article

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description: